A2V Gear’s CBC421 series with this unique fibre optical cable system let your digital LCD monitor extend up to 300 meter (984 feet) away from host without any external power supply based on DVI standard.
Technical Specifications
Key Features
High Speed and long distance transmission by Optical System
Fully compatible with DVI standard by DDWG
The use of Standard DVI-D Plug
Either external or internal power supply is possible (External Power supply is optional, automatic power switch is include
R.G.B. Clock signal is transmitted by Optical fibre
DDC Signal and 5V Power line is transmitted by copper lin
Optional Fibre only system without DDC function (PSEUDO DDC Signal can be transmitted for EDID information)
No EMI characteristics for medical instruments and airplane
General Specification
Frequency Bandwidth:
1.65 Gbps (Single Link)
Supporting Graphic Resolution & Distance:
Type A: WUXGA Resolution (1920x 1200) 60Hz 100m (330ft)
Model: CBC421 A*1 Fully compatible with DVI1.0 including of DDC and hot plug detection
Pin
Signal Assignment
Pin
Signal Assignment
Pin
Signal Assignment
1
T.M.D.S. Data2-
9
T.M.D.S. Data1-
17
T.M.D.S. Data0-
2
T.M.D.S. Data2+
10
T.M.D.S. Data1+
18
T.M.D.S. Data0+
3
T.M.D.S. Data2 Shield
11
T.M.D.S. Data1 Shield
19
T.M.D.S. Data0 Shield
4
No Connect
12
No Connect
20
No Connect
5
No Connect
13
No Connect
21
No Connect
6
DDC Clock
14
+5V Power
22
T.M.D.S. Clock Shield
7
DDC Data
15
Ground (for +5V)
23
T.M.D.S. Clock+
8
No Connect
16
Hot Plug Detect
24
T.M.D.S. Clock-
CBC422-R001 : Receiver Module
Pin
Signal Assignment
Pin
Signal Assignment
Pin
Signal Assignment
1
T.M.D.S. Data2-
9
T.M.D.S. Data1-
17
T.M.D.S. Data0-
2
T.M.D.S. Data2+
10
T.M.D.S. Data1+
18
T.M.D.S. Data0+
3
T.M.D.S. Data2 Shied
11
T.M.D.S. Data1 Shield
19
T.M.D.S. Data0 Shield
4
No Connect
12
No Connect
20
No Connect
5
No Connect
13
No Connect
21
No Connect
6
No Connect
14
Out +5v power
22
T.M.D.S. Clock Shield
7
No Connect
15
Ground(for Out +5v)
23
T.M.D.S. Clock+
8
No Connect
16
No Connect
24
T.M.D.S. Clock-
*1: 4 Fiber & 5 Copper line Cable Construction
-Model : CBC421-B*2 - - -Only R,G,B,Clock signal is transmitted by optical fiber without DDC and Power lines - - -For DDC interconnection, EDID information can be transmitted to computer by DDC chip inside transmitter module
Pin
Signal Assignment
Pin
Signal Assignment
Pin
Signal Assignment
1
T.M.D.S. Data2-
9
T.M.D.S. Data1-
17
T.M.D.S. Data0-
2
T.M.D.S. Data2+
10
T.M.D.S. Data1+
18
T.M.D.S. Data0+
3
T.M.D.S. Data2 Shield
11
T.M.D.S. Data1 Shield
19
T.M.D.S. Data0 Shield
4
No Connect
12
No Connect
20
No Connect
5
No Connect
13
No Connect
21
No Connect
6
No Connect
14
+5V Power
22
T.M.D.S. Clock Shield
7
No Connect
15
Ground (for +5V)
23
T.M.D.S. Clock+
8
No Connect
16
No Connect
24
T.M.D.S. Clock-
*2 : Only 4 Fiber Cable Construction, No DDC & Hot Plug Detection Function